Lucerne V8-4.6L (2008)
Important: Reuse the condenser line mounting bracket.
3. Install the condenser line to radiator mounting bolt.
Tighten the bolts to 6 N.m (53 lb in).
4. Install new sealing washers. Refer to Sealing Washer Replacement (See: Coupler HVAC/A/C Coupler O-ring/Service and Repair/Sealing Washer
Replacement).
5. Install the suction hose to the condenser.
6. Install the suction hose nut to the condenser.
Tighten the nut to 16 N.m (12 lb ft).