7. Install the liquid line to the condenser.
8. Install the liquid line nut to the condenser.

Tighten the nut to 16 N.m (12 lb ft).

9. Install the hood latch bracket. Refer to Hood Latch Support Replacement  (See: Body and Frame/Doors, Hood and Trunk/Hood/Hood

Latch/Service and Repair).

10. Recharge the A/C system. Refer to Refrigerant Recovery and Recharging (Non HP2)  (See: Service and Repair/Refrigerant Recovery and

Recharging (Non HP2)).

11. Leak test the fittings using the J 39400-A.
12. Install the front compartment sight shield. Refer to Front Compartment Sight Shields Replacement  (See: Body and Frame/Spoilers, Flaps, and Air

Dams/Air Dam/Service and Repair/Front Compartment Sight Shields Replacement).