buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Exhaust Gas Recirculation > < Evaporative Emissions Hose|Service and Repair|Page 5247
Page 6
background image

10. Connect the EVAP line (2) quick connect fitting at the EVAP canister purge valve. Refer to Plastic Collar Quick Connect Fitting Service  (See:

Fuel Delivery and Air Induction/Fuel Line Coupler/Service and Repair/Plastic Collar Quick Connect Fitting Service).

11. Connect the fuel feed pipe (1) quick connect fitting at the fuel rail. Refer to Metal Collar Quick Connect Fitting Service  (See: Fuel Delivery and

Air Induction/Fuel Line Coupler/Service and Repair/Metal Collar Quick Connect Fitting Service).

12. Connect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection  (See: Starting and Charging/Battery/Battery

Cable/Service and Repair).

13. Perform the following procedure in order to inspect for leaks:

1. Turn ON the ignition, with the engine OFF for 2 seconds.
2. Turn OFF the ignition for 10 seconds.
3. Turn ON the ignition, with the engine OFF.
4. Inspect for fuel leaks.

14. Install the fuel injector sight shield. Refer to Fuel Injector Sight Shield Replacement  (See: Fuel Delivery and Air Induction/Fuel Injector/Service

and Repair/Fuel Injector Sight Shield Replacement).

Exhaust Gas Recirculation > < Evaporative Emissions Hose|Service and Repair|Page 5247