Park Avenue V6-231 3.8L VIN L SFI (1993)
Positive Crankcase Ventilation Valve: Service and Repair
PCV Valve Installation
1.
Remove PCV valve cover plate fastening bolts.
2.
Remove cover plate and gasket.
3.
Remove spring, PCV valve, and O-ring.
4.
Clean old gasket material from surfaces and install new valve in reverse order.