Door Module: Diagnostic Aids
Testing For a Short To Voltage

TESTING FOR A SHORT TO VOLTAGE

NOTE:  Refer to Test Probe Notice in Service Precautions.

The following procedure tests for a short to voltage in a circuit.
1. Set the rotary dial of the DMM to the V (DC) position.
2. Connect the positive lead of the DMM to 1 end of the circuit to be tested.
3. Connect the negative lead of the DMM to a good ground.
4. Turn ON the ignition and operate all accessories.
5. If the voltage measured is greater than 1 volt, there is a short to voltage in the circuit.