Horn: Diagnostic Aids
Troubleshooting With A Test Lamp

TROUBLESHOOTING WITH A TEST LAMP

TOOLS REQUIRED

J 35616-200 12-Volt Unpowered Test Lamp

NOTE:  Refer to Test Probe Notice in Service Precautions.

A test lamp can simply and quickly test a low impedance circuit for voltage.

The J 35616-200 is Micro-Pack compatible and comprised of a 12-volt light bulb with an attached pair of leads.

To properly operate this tool use the following procedures.

When testing for voltage:
1. Attach 1 lead to ground.
2. Touch the other lead to various points along the circuit where voltage should be present.
3. When the bulb illuminates, there is voltage at the point being tested.

When testing for ground:
1. Attach 1 lead to battery positive voltage.
2. Touch the other lead to various points along the circuit where ground should be present.
3. When the bulb illuminates, there is ground at the point being tested.