buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Air Cleaner Housing > < Fuel Pressure Gage Installation and Removal|Page 1692
Page 5
background image

Steps 20-25

The numbers below refer to the step numbers on the diagnostic table.
2. This step verifies that the fuel pump is operating.
4. This step tests for an internal fuel leak. If the fuel pressure decreases during this test, an internal loss of pressure is indicated.
6. This step tests the fuel pressure regulator. The fuel pressure regulator is controlled by engine vacuum. With engine vacuum applied, the pressure

should decrease by the specified value.

9. This step inspects the fuel pressure regulator for a fuel leak from the vacuum port. If fuel leaks from the fuel pressure regulator while the fuel

pump is commanded ON, replace the fuel pressure regulator.

10. This step tests for a loss of fuel pressure between the shut-off adapter on the fuel feed pipe and the fuel pump.
11. This step tests for a leaking fuel injector, or fuel pressure regulator. If the fuel pressure remains constant during this test, the fuel injectors are not

leaking fuel.

14. This step tests for a restricted fuel return pipe. If the fuel pressure is within the specified values, a restriction in the fuel return pipe is indicated.
16. This step determines if the fuel pressure regulator, or the fuel pump, is the cause of the low fuel pressure. If the pressure rises above the specified

value, the fuel pump is OK.

18. This step verifies that a circuit condition is not the cause of a fuel pressure concern. Inspect all fuel pump electrical circuits thoroughly.

Air Cleaner Housing > < Fuel Pressure Gage Installation and Removal|Page 1692