1. Connect the horn ground lead (2) into the lower left threaded hole in the steering wheel.
2. Connect the horn contact lead into the steering column cam tower.
3. Rotate the horn contact turn 1/4 turn clockwise in order to lock.
4. Connect the inflator module electrical connector and the CPA (4).
5. Align the driver inflator module fasteners to the steering column fastener holes.

-

The driver inflator wires

-

The redundant control wires

-

The horn wires

IMPORTANT:  Route the following wires correctly:

6. Push the driver inflator module firmly into the steering column in order to engage the fasteners.
7. Enable the SIR system. Refer to SIR Disabling and Enabling Zone 3.