Park Avenue V6-3.8L SC VIN 1 (2005)
6. Notice: Refer to Fastener Notice in Service Precautions.
Install the oil pump bolts (206, 207).
^
Tighten the bolts (207) to 12 Nm (106 inch lbs.)
^
Tighten the bolts (206) to 16 Nm (12 ft. lbs.)
7. Reposition and connect the electrical connectors to the following:
^
The Transmission Fluid Pressure (TFP) manual valve position switch (395)
^
The 2-3 shift solenoid valve assembly (315B)
^
The internal mode switch if equipped
8. Install the case side cover.