buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Air Cleaner Fresh Air Duct/Hose|Service and Repair|Page 7451 > < Idle Speed|Specifications
Page 1
background image

Air Cleaner Fresh Air Duct/Hose: Service and Repair

Air Cleaner Outlet Resonator Replacement

Removal Procedure

1.  Loosen the air cleaner outlet duct and air cleaner outlet resonator clamps (2).
2.  Disconnect the air cleaner outlet duct from the air cleaner outlet resonator (3).

3.  Remove the 2 air cleaner outlet resonator to engine bolts (4).
4.  Disconnect the crankcase ventilation hose (1) from the valve cover port (2).
5.  Disconnect the electrical connector to the intake air temperature (IAT) sensor.
6.  Remove the air cleaner outlet resonator assembly (5) from the engine.

Installation Procedure

1.  Connect the electrical connector to the IAT sensor.

2.  Install the air cleaner outlet resonator assembly (5) to the engine making sure of the following:

*  The crankcase ventilation hose (1) is connected to the valve cover port (2).
*  The air cleaner outlet resonator (5) is properly fit to the throttle body assembly.

Notice:  Refer to Fastener Notice.

3.  Install the 2 air cleaner outlet resonator to engine bolts (4).

Air Cleaner Fresh Air Duct/Hose|Service and Repair|Page 7451 > < Idle Speed|Specifications