buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Inducing Intermittent Fault Conditions|Page 2929 > < Inducing Intermittent Fault Conditions|Page 2927
Page 1
background image

Knock Sensor: Diagnostic Aids
Testing for Short to Ground

TESTING FOR SHORT TO GROUND

NOTE:  Refer to Test Probe Notice.

The following procedures test for a short to ground in a circuit.

With a DMM
1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Set the rotary dial of the DMM to the ohm position.
4. Connect one lead of the DMM to one end of the circuit to be tested.
5. Connect the other lead of the DMM to a good ground.
6. If the DMM does NOT display infinite resistance (OL), there is a short to ground in the circuit.

With a Test Lamp
1. Remove the power feed (i.e. fuse, control module) from the suspect circuit.
2. Disconnect the load.
3. Connect one lead of the test lamp to battery positive voltage.
4. Connect the other lead of the test lamp to one end of the circuit to be tested.
5. If the test lamp illuminates, there is a short to ground in the circuit.

Fuse Powering Several Loads
1. Review the system schematic and locate the fuse that is open.
2. Open the first connector or switch leading from the fuse to each load.
3. Connect a DMM across the fuse terminals (be sure that the fuse is powered).

-

When the DMM displays voltage the short is in the wiring leading to the first connector or switch.

-

If the DMM does not display voltage

4. Close each connector or switch until the DMM displays voltage in order to find which circuit is shorted.

Inducing Intermittent Fault Conditions|Page 2929 > < Inducing Intermittent Fault Conditions|Page 2927