Do NOT replace an EV fan unless a specific condition related to the EV fan is identified using SI diagnostics. If the fan has a condition that warrants
replacement, a DTC should set and/or SI diagnostics should lead to the replacement of the fan clutch.

If the fan is not operating at the proper speed/function, the appropriate diagnostic trouble code should set.

Identify the root cause of the condition. Please make sure to do a thorough review of SI for proper diagnostics. Several Service Bulletins and Preliminary
Information are available on SI regarding the EV fan.

Refer to "Operating Characteristics" and "Diagnostic Tips" in this bulletin for additional information.

Operating Characteristics of the Electro-Viscous (EV) Fan Clutch

Changes to the EV fan clutch to improve the HVAC performance basically increase airflow in certain conditions. It is now possible during start up for
the EV fan clutch to be engaged and match engine speed for about 1 minute depending on driving speeds (with lower speeds having a longer
disengagement time) producing some noise/flare. The noise/flare will most likely be intermittent and can be dependent on the following conditions:

^

Fan clutch valve orientation, with check ball at 11:00 position as viewed from front of vehicle when the engine is stopped.

^

HVAC or powertrain cooling conditions when the vehicle is shut off.

^

Parking incline - vehicles parked nose up on a 16% or higher incline (such as vehicles coming off transport or parked on steep driveways) may have
prolonged fan noise/flare until the fluid is pumped out of the working chamber of the fan. These conditions can occur in as little as ten minutes. Once
the vehicle is not parked in these conditions, it should operate as expected.

^

Please note that if the vehicle is parked nose down with a 16% or more decline, the EV fan clutch may have a delayed engagement response similar
to what is described in Corporate Bulletin Number 04-01-38-019A.

Important:

Do not replace EV fan clutches for these conditions listed above; they are expected vehicle characteristics. If the fan clutch is truly operating at a
speed higher than intended, a DTC P0495 or P1484 should set. Additional codes are available for other conditions.

Diagnostic Tips

Depending on the vehicle year, the Tech 2(R) may allow some EV fan control using the special functions application of the Tech 2 (refer to the proper SI
documentation). If this function or a fused jumper wire is being used to check EV fan response, there may be a delay in fan response (up to 2-3 minutes
depending on conditions, please refer to SI diagnostics).

The desired fan speed and actual fan speed data (on the Tech 2(R)) can be misleading. The desired fan speed is comprised of the maximum of multiple
parameters (for example engine coolant temp, A/C pressure, etc.) and may not be the ruling desired fan speed parameter. The end result may be that the
actual desired fan speed is lower than what is displayed. 

Additionally, the desired fan speed may be higher than the current engine speed. The fan is limited by the current engine RPM and will max out at about
3500 RPM under full manual fan engagement request along with a corresponding engine RPM speed. The 4.2L 1-6 (LL8) engine's desired and actual fan
speeds will usually be closer to each other than the 5.3L V-8 (LM4 or LH6) or the 6.0L V-8 (LS2).

Disclaimer