3. Depress the spring loaded locator of the crimping tool until the terminal holder is completely visible.

4. Insert terminal into the appropriate terminal holder until it hits bottom and stops. The correct terminal holder is determined by the wire size. Also

ensure that the terminals wings are pointing towards the former on the tool and the release locator.

5. Insert the stripped cable into the terminal. Insulation should be visible on both sides of the terminal insulation wings.
6. Compress the handles until the ratchet automatically releases.
7. Place the terminal into the appropriate cavity and assemble the connector.