buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Brake Pedal Position Sensor Calibration|Page 7987 > < Pedal Positioning Sensor|Diagrams
Page 1
background image

Pedal Positioning Sensor: Service and Repair
Brake Pedal Position Sensor Calibration

Brake Pedal Position Sensor Calibration

Calibration Criteria

Note:  Do not apply the brake pedal during the brake pedal position sensor calibration procedure. Any movement of the brake pedal during this
procedure will cause the calibration procedure to fail. If this occurs, the brake pedal position sensor calibration must be repeated.

Brake pedal position sensor calibration must be performed after the brake pedal position sensor or body control module (BCM) have been serviced. The
calibration procedure will set the brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying
the brake system and to provide this information to the vehicle subsystems via serial data.

Calibration Procedure

1. Apply the parking brake.
2. Place the transmission in the PARK position.
3. Install a scan tool.
4. Navigate to the Module Diagnosis menu.
5. Clear all BCM DTCs before proceeding.
6. Navigate to the Configuration/Reset Functions menu of the BCM.
7. Select Brake Pedal Position Sensor Learn.
8. Select the Brake Pedal Position Sensor Learn procedure and follow the directions displayed on the screen.

Brake Pedal Position Sensor Calibration|Page 7987 > < Pedal Positioning Sensor|Diagrams