Regal L4-2.0L Turbo (2011)
Terminal Insertion Procedure
1. In order to reuse a terminal or lead assembly, refer to Wiring Repairs (See: Testing and Inspection/Component Tests and General
Diagnostics/General Electrical Diagnostic Procedures/Wiring Repairs/Wiring Repairs).
2. Ensure that the cable seal is kept on the terminal side of the splice.
3. Insert the lead from the back until it catches.
4. Install the TPA, CPA, and/or the secondary locks.