buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Symptoms - Data Communications|Page 3255 > < Symptoms - Data Communications|Page 3253
Page 3
background image

‹› If less than 35 ohm, test for a short between the serial data circuits. Refer to Testing the Serial Data Circuits for a Short between the Circuits.
‹› If 35-50 ohm there may be a third terminating resistor between the serial data circuits. This can happen if the incorrect control module is

installed. Some control modules are available with and without the terminating resistors installed to reduce the need of terminating resistors in
the wiring harness.

‹› If greater than 70 ohm but less than infinite, test the serial data circuit for an open/high resistance. Refer to Testing the Serial Data Circuits for

an Open/High Resistance.

‹› If infinite, test the serial data circuits between the DLC and the first connection to the serial data circuit for an open/high resistance.

Testing the Serial Data Circuits for a Short to Voltage

1. Ignition OFF, disconnect the harness connectors with the mid speed GMLAN serial data circuits at an easily accessible control module.
2. Ignition ON, test for greater than 4.5 V between each serial data circuit at the control module connector that was just disconnected and ground.

Verify that one or more serial data circuits are greater than 4.5 V.

‹› If all serial data circuits are less than the specified range, replace the control module that was disconnected.

3. Ignition OFF, disconnect the harness connectors with the mid speed GMLAN serial data circuits at another control module, in the direction of the

circuit shorted to voltage.

4. Ignition ON, test for greater than 4.5 V between the serial data circuits at the control module connector that was just disconnected and ground.

Verify that one or more serial data circuits are greater than 4.5 V.

‹› If all serial data circuits are less than the specified range, replace the control module that was just disconnected.

5. Repeat step 3 until one of the follow conditions are isolated:

*

A short to voltage on the serial data circuit between 2 control modules or splice packs, if equipped

*

A short to voltage on the serial data circuit between a control module and a terminating resistor

Testing the Serial Data Circuits for a Short to Ground

1. Ignition OFF, disconnect the harness connectors with the mid speed GMLAN serial data circuits at an easily accessible control module.
2. Ignition OFF for 60 seconds, test for less than 1k ohm between each serial data circuit at the control module connector that was just disconnected

and ground. Verify that one or more serial data circuits are less than 1k ohm.

‹› If all serial data circuits are greater than the specified range, replace the control module that was disconnected.

3. Disconnect the harness connectors with the mid speed GMLAN serial data circuits at another control module, in the direction of the circuit shorted

to ground.

4. Ignition OFF for 60 seconds, test for less than 1k ohm between the serial data circuits at the control module connector that was just disconnected

and ground. Verify that one or more serial data circuits are less than 1k ohm.

‹› If greater than the specified range for all serial data circuits, replace the control module that was just disconnected.

5. Repeat step 3 until one of the follow conditions are isolated:

*

A short to ground on the serial data circuit between 2 control modules or splice packs, if equipped

*

A short to ground on the serial data circuit between a control module and a terminating resistor

Testing the Serial Data Circuits for a Short between the Circuits

1. Ignition OFF, disconnect the harness connectors with the mid speed GMLAN serial data circuits at an easily accessible control module that is not

communicating.

2. Ignition OFF for 60 seconds, test for less than 35 ohm between each pair of serial data circuits at the control module connector that was just

disconnected. Verify that one pair of serial data circuits are less than 35 ohm. 

‹› If each pair of serial data circuits is greater than the specified range, replace the control module that was disconnected.

3. Connect the harness connectors at the control module that was disconnected.
4. Disconnect the harness connectors with the mid speed GMLAN serial data circuits at another control module, in the direction of the circuits

shorted together.

5. Ignition OFF for 60 seconds, test for less than 35 ohm between each pair of serial data circuits at the control module connector that was just

disconnected. Verify that one pair of serial data circuits are less than 35 ohm. 

‹› If each pair of serial data circuits is within the specified range, replace the control module that was just disconnected.

6. Repeat step 3 until one of the following conditions are isolated:

*

Serial data circuits shorted together between 2 control modules or splice packs, if equipped

Symptoms - Data Communications|Page 3255 > < Symptoms - Data Communications|Page 3253