buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

A/C - Odor at Start Up in Hot Humid Climates|Page 5980 > < A/C - Odor at Start Up in Hot Humid Climates|Page 5978
Page 1
background image

Evaporator Core: Customer Interest
Afterblow Module Test Procedure

TO TEST THE AFTERBLOW MODULE USE THE FOLLOWING PROCEDURE

1. Start the engine.

2. Turn the A/C system to engage the compressor.

3. Connect a jumper wire to apply battery voltage to the open cavity Pin H (Green Wire) of the afterblow module for at least thirty (30 seconds)

with the compressor engaged.

4. Turn the ignition key off.

5. The blower should come on after approximately ten (10) seconds for one

(1) second and then go off.

6. Disconnect the jumper wire.

NOTICE:

The afterblow module is not compatible with some non-factory installed theft alarm systems. The module current draw at key off position
could trigger alarms that sense battery voltage changes or current drain.

ADVISE OWNER that the afterblow module will enable the blower motor to run at high speed for five (5) minutes approximately fifty (50)
minutes after the vehicle ignition is turned off, if the A/C compressor was engaged for at least four (4) minutes or more during last ignition
cycle.

A/C - Odor at Start Up in Hot Humid Climates|Page 5980 > < A/C - Odor at Start Up in Hot Humid Climates|Page 5978