PROM - Programmable Read Only Memory: All Technical Service Bulletins
A/C Compressor - Operation During Start-Up

Bulletin 91-6E-8

Date Feb. '91

Ref. No. 91-083-6E

Corp. Ref. No. 006505

SUBJECT: A/C COMPRESSOR OPERATION DURING START-UP TO CONTROL RPM FLARE VEHICLES EQUIPPED WITH THE 3800 T.P.I.

ENGINE (VIN L)

MODELS AFFECTED:

1991 PARK AVENUE ULTRA WITH 3800 T.P.I. ENGINE (VIN L) BUILT PRIOR TO M1626149, 1990-91 REGAL
MODELS, FEDERAL EMISSIONS - BUILT PRIOR TO M1813629, 1990-91 REGAL MODELS, CALIFORNIA
EMISSIONS, BUILT PRIOR TO M1813961

From start of production, the above vehicles with listed serial numbers, allows during each ignition cycle the A/C compressor to engage, up to five
seconds, to minimize engine RPM flare with the A/C mode switch in the on or off position.  A/C compressor engagement during start-up on vehicles that
have a sudden loss of refrigerant or have lost all the refrigerant over a period of time, may contribute to an A/C compressor failure.

If a technician is servicing the A/C system on a vehicle built prior to the breakpoint listed, it is recommended that a new calibration mem-cal be installed,
in conjunction with the A/C system repairs.

The new calibration will eliminate A/C compressor operation during engine start-up.

The mem-cals are currently available through GMSPO under the following part numbers.
 
                                      

SCANNER 

                                      

ID IF

                  

APPLI-

AXLE

MEM-CAL

BROAD-

SERVICE

YEAR

MODEL

CATION

RATIO

INSTALLED CAST

PART #

1991

Park Ave./Ultra

Fed.

F17/2.84

9994

AXDH

16160178

1991

Park Ave./Ultra

Calif.

F17/2.84

0004

AXDJ

16160173

1991

Park Ave./Ultra

Fed.

opt. 3.06 *

0014

AXDK

16160168

1991

Park Ave./Ultra

Calif.

opt. 3.06 *

0024

AXDL

16160163

1990-91 Regal

Fed.

All

0044

AXDN

16160153

1990-91 Regal

Calif.

All

0054

AXDP

16160148

*

Part of Option Package      Y56 or  V92

IMPORTANT:

The new calibration mem-cals are currently being used in production. Verify if this mem-cal is already installed by the scanner I.D.

WARRANTY INFORMATION:

Use applicable Labor Time Guide Operation Number and Time.