buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Pulsed Secondary Air Injection > < All Technical Service Bulletins for Air Injection Pump Pulley:|846E1
Page 1
background image

Air Injection Pump Pulley: Customer Interest
A.I.R. Pump - Rattling Noise

Bulletin      

84-6E-1

Date        

Nov. '83

Ref. No.     

84-031-6

SUBJECT:

REVISED TORQUE PROCEDURE FOR A.I.R. PUMP PULLEY BOLTS

MODELS AFFFECTED: ALL 1983 AND 1984 PASSENGER CARS EQUIPPED WITH A.I.R. SYSTEMS
A rattling noise from the engine compartment may be experienced due to loose A.I.R. pump pulley attaching bolts.

The following procedure must be used to correct this condition:

1.

Remove the drive belt from the A.I.R pump pulley.

2.

Remove three (3) A.I.R pump pulley attaching bolts and discard.

3.

Inspect and remove any foreign material from the pulley and the pulley mounting surface on the pump.

4.

Replace the pump and/or pulley if they have been damaged. (Elongated holes or stripped threads.)

5.

Replace the pulley using, three (3) bolts, P/N 14063759. Use torque wrench to torque all three (3) bolts to 14 N-m (124 in.lbs.).

6.

Immediately recheck the bolts to insure they have not lost torque.

7.

If specified torque cannot be reached, inspect pump threads for stripping and replace as necessary.

8.

Replace and retension the belt.

Use applicable labor times.

Pulsed Secondary Air Injection > < All Technical Service Bulletins for Air Injection Pump Pulley:|846E1