Control Assembly: All Technical Service Bulletins
Blower Motor - Run On When Ignition is Off

File In Section: 1 - HVAC

Bulletin No.: 83-11-10

Date: February, 1998

Subject: 
Blower Motor Run On When Ignition Is Off 
(Replace Control Assembly)

Models: 
1997 Buick Century, Regal
1997 Chevrolet Corvette

Condition

Some vehicles equipped with automatic temperature control (RPO CJ2) may experience an HVAC blower motor run on condition after the ignition is
turned off. This condition can occur approximately once every 1400 ignition cycles. Cycling the ignition switch back to the "ON" position will stop the
blower motor from running.

Cause

This run on condition was found in the software of the CJ2 HVAC Control Assembly.

Correction

Replace the Control Assembly following the procedures in the appropriate section of the Service Manual.

Parts Information

P/N

Description

09356081

Control, Assembly Heater & A/C (97 Corvette)

09356104

Control, Assembly Heater & A/C (97 Century/Regal)

Parts are currently available through GMSPO.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time    

D0362

Control Assembly

Use Published Labor Operation 
Time

Replace