Deformation Of A Typical Metri-Pack 150/280/480/630 Series Female Terminal

Deformation is caused by probing the mating side of a connector terminal without the proper adapter, improperly joining the connector halves or
repeatedly separating and joining the connector halves. Deformation, usually to the female terminal contact tang, can result in poor terminal
contact, causing an open or intermittently open circuit.

PROCEDURE

Follow the procedure below to check terminal contact.
1. Separate the connector halves. Refer to Terminal Repair Kit, J 38125-A, J 38125-4.
2. Inspect the connector halves for contamination. Contamination will result in a white or green build-up within the connector body or between

terminals, causing HI terminal resistance, intermittent contact or an open circuit. An underhood or underbody connector that shows signs of
contamination should be replaced in its entirety: terminals, seals and connector body.

3. Using an equivalent male terminal from the Terminal Repair Kit, J 38125-A, check the retention force of the female terminal in question by

inserting and removing the male terminal to the female terminal in the connector body. Good terminal contact will require a certain amount of

Additional Information|Page 4455 > < Additional Information|Page 4453