buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Atmospheric Leak Check Procedure|Page 10902 > < Atmospheric Leak Check Procedure|Page 10900
Page 1
background image

Vacuum Modulator: Service and Repair

REMOVE OR DISCONNECT

1. Air cleaner duct. Refer to POWERTRAIN MANAGEMENT.
2. Vacuum modulator and wiring harness shield.
3. Vacuum line at modulator.
4. Electrical connector from transaxle case.
5. Attaching bolt/screw and clamp at modulator base.
6. Vacuum modulator and O-ring.

-

Use care to avoid losing modulator valve from transaxle case.

INSTALL OR CONNECT    

NOTICE:  Always use the correct fastener in the proper location. When you replace a fastener, use ONLY the exact part number for that application.
The manufacturer will call out those fasteners that require a replacement after removal. The manufacturer will also call out the fasteners that require
thread lockers or thread sealant. UNLESS OTHERWISE SPECIFIED, do not use supplemental coatings (paints, greases, or other corrosion inhibitors)
on threaded fasteners or fastener joint interfaces. Generally, such coatings adversely affect the fastener torque and the joint clamping force, and may
damage the fastener. When you install fasteners, use the correct tightening sequence and specifications. Following these instructions can help you
avoid damage to parts and systems.

1. Vacuum modulator and new O-ring. 
2. Clamp and attaching bolt screw.

-

Tighten bolt/screw to 27 Nm (20 ft. lbs.).

Atmospheric Leak Check Procedure|Page 10902 > < Atmospheric Leak Check Procedure|Page 10900