Regal V6-3.8L VIN K (1997)
Vacuum Modulator: Testing and Inspection
Load Check Procedure
^
Tool Required:
-
J 36619 Modulator Comparison Gage
Perform the following steps to inspect the load:
1. Install a known good modulator of the same type on one side of the J 36619 Modulator Comparison Gage.
2. Install the modulator to be tested on other side of the J 36619 Modulator Comparison Gage
3. Hold the assembly level.
4. Slowly push the two modulators together.
-
The modulator is not acceptable if the gage line remains blue.
-
The modulator is acceptable if the gage line is white.