Vacuum Modulator: Testing and Inspection
Load Check Procedure

^

Tool Required:
-

J 36619 Modulator Comparison Gage 

Perform the following steps to inspect the load:
1. Install a known good modulator of the same type on one side of the J 36619 Modulator Comparison Gage.
2. Install the modulator to be tested on other side of the J 36619 Modulator Comparison Gage
3. Hold the assembly level.
4. Slowly push the two modulators together. 

-

The modulator is not acceptable if the gage line remains blue. 

-

The modulator is acceptable if the gage line is white.