Regal V6-3.8L VIN K (1997)
Vacuum Modulator: Testing and Inspection
Load Check
^
Tool Required:
-
J 36619 Modulator Comparison Gage
Inspect
1. Install a known good modulator of the same type on one side of J 36619.
2. Install the modulator to be tested on the other side of J 36619.
3. Holding the assembly level, slowly push the two modulators together.
-
If the gage line remains blue, the modulator is not acceptable.
-
If the gage line is white, the modulator is acceptable.