Rendezvous V6-3.5L (2007)
Hose/Line HVAC: Service and Repair
Discharge Hose Replacement (LX9)
Discharge Hose Replacement (LX9)
Tools Required
J39400-A Halogen Leak Detector
Removal Procedure
1. Remove the air cleaner assembly.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Remove the discharge hose to condenser nut.
4. Disconnect the discharge hose from the condenser.
Important: Cap or tape the open A/C components immediately to prevent A/C system contamination.
5. Cap or tape the discharge port on the condenser.
6. Remove the lower air baffle.
7. Remove the discharge hose to compressor nut.
8. Disconnect the discharge hose from the compressor.
9. Cap or tape the compressor discharge port.
10. Remove the discharge hose.
11. Remove and discard the sealing washers.