Rendezvous V6-3.5L (2007)
10. Install the evaporator outlet tube nut.
Tighten the nut to 16 N.m (12 lb ft).
11. Install the evaporator inlet tube clamp nut.
Tighten the nut to 3.3 N.m (29 lb in).
12. Install the A/C pressure sensor to the evaporator inlet tube.
Tighten the sensor to 5 N.m (44 lb in).
13. Connect the electrical connector to the A/C pressure sensor.
14. Install the wiper motor module.
15. Install the air cleaner assembly.
16. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
17. Leak test the fittings of the component using J39400-A.