Rendezvous AWD V6-3.6L VIN 7 (2004)
4. Connect the suction hose to the compressor.
NOTE: Refer to Fastener Notice in Service Precautions.
5. Install the nut that secures the suction hose to the compressor.
Tighten
Tighten the nut to 16 N.m (12 lb ft).
6. Install a new sealing washer between the suction hose and the evaporator outlet tube fitting.
7. Remove the cap or tape from the evaporator outlet tube.
8. Connect the suction hose to the evaporator outlet tube fitting.
9. Install the bolt to secure the suction hose to the evaporator outlet tube.
Tighten
Tighten the bolt to 16 N.m (12 lb ft).
10. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
11. Use J 39400-A to leak test the fittings of the component
12. Connect the negative battery cable.