Rendezvous AWD V6-3.6L VIN 7 (2004)
INSTALLATION PROCEDURE
1. Install the CMP sensor.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Install the CMP sensor bolt.
Tighten the CMP sensor bolt to 10 N.m (89 lb in).
3. Install the CMP sensor electrical connector (2).
4. Install the power steering fluid reservoir.