Roadmaster V8-305 5.0L (1992)
Air Door Actuator / Motor: Service and Repair
Air Inlet Valve Vacuum Actuator
AIR INLET VALVE VACUUM ACTUATOR
REMOVE OR DISCONNECT
1. Instrument panel carrier.
2. Vacuum hose.
^
Disconnect the vacuum hose connector at the air inlet valve actuator (9) by sliding the tab of the connector retainer past the L-shaped bend in
the vacuum tube. Then slide the connector off the tube while continuing to hold the tab back against the body of the connector.
3. Air inlet valve actuator (9).
^
With a thin-blade screwdriver, disengage the catch locking the air inlet valve actuator (9) to the air conditioning module (1) and slide the air
inlet valve actuator (9) away to remove it.