buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Master Cylinder Assembly|Page 4446 > < Master Cylinder Assembly
Page 2
background image

Fluid Level Sensor Switch

-

Install fluid level sensor switch until locking tabs snap in place.

-

Install electrical connector to fluid level sensor switch.

Proportioner Valve Assembly

 Proportioner Valve Cap Assemblies

-

Clean all parts in clean, denatured alcohol and dry with unlubricated compressed air.

-

Lubricate new "0" rings and proportioner valve seals with silicone grease supplied in repair kit. Also lubricate stem of proportioner valve
pistons.

-

Install new seals on proportioner valve pistons with seal lips facing upward toward cap assembly.

-

Install proportioner valve pistons and seals in master cylinder body.

-

Install springs in master cylinder body.

-

Install new "0" rings in grooves in proportioner valve cap assemblies.

-

Install proportioner valve caps in master cylinder body and torque to 27 Nm (20 lbs. ft.).

-

Install reservoir assembly, if removed. 

7.

Fit diaphragm into reservoir cover, then install cover onto reservoir.

8.

Install master cylinder in vehicle. See: Master Cylinder Installation