Coolant: Testing and Inspection

TYPES OF ANTI FREEZE

Some coolant manufacturers are mixing other types of glycol in their coolant formulations; propylene glycol is the most common new ingredient.
A hydrometer will not always provide a correct measurement of freeze protection when anything other than ethylene glycol and water is being
tested. The degree of inaccuracy will vary depending on the proportion of other glycols present in the coolant. Hydrometers test the amount of
glycol in a mixture by measuring the specific gravity of the mixture; the more ethylene glycol, the higher the float balls go, and the better the
freeze protection.

 
REFRACTOMETER TESTING

Because ethylene glycol and propylene glycol do not have the same specific gravities, hydrometer readings of mixtures containing propylene
glycol give incorrect values. It is recommended that a "refractometer" be used when testing coolant. Refractometers test for the amount of glycol in
a coolant mixture by measuring the speed of light as it passes through the fluid and are not affected by the specific gravity of the glycol. 

Fluid - A/T > < 00-06-02-006D|Page 734