Skylark L4-151 2.5L (1991)
Remove or Disconnect
1. Regulator from door.
2. Motor from regulator using 3/16" drill bit.
Install or Connect
1. Motor to regulator using 3/16" rivets (nuts and bolts may be used).
2. Window regulator.
Regulator Tape
Important
^
When cutting service tape, it is necessary to cut tape so that there is a half a notch at each end of the tape. This is done to insure proper
indexing of the tape when installed. Tape lengths are as follows:
^
2 Door Front Door Manual 1 190.7 mm (46.87") 146 full holes plus 1/2 hole each end.
^
2 Door Front Door Electric 1 044.7 mm (41.13") 128 full boles plus 1/2 hole each end.
^
4 Door Front Door Manual 1 287.9 mm (50.70") 158 full holes plus 1/2 hole each end.
^
4 Door Front Door Electric 1 142.1 mm (44.96") 140 full holes plus 1/2 hole each end.
Remove or Disconnect