buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

09-06-03-004D|Page 3469 > < 09-06-03-004D|Page 3467
Page 4
background image

Tighten
Tighten to 8 Nm (71 lb in). 

Note
The repair area MUST BE properly refinished to maintain a secure, stable and corrosion-free electrical ground. 

12. Refinish the repair area using an anti-corrosion primer. Refer to Anti-Corrosion Treatment and Repair in SI.
13. Verify proper system operation.

M8 Weld Nut

Caution

Use only the GM-approved replacement fasteners with conductive finish for electrical ground repair.

1. If the M8 weld nut electrical ground location is accessible from both sides of the panel, a M8 conductive bolt and a M8 conductive nut may be

used to secure the electrical ground wire terminal. Refer to the Parts Information section of this bulletin.

2. Select a location adjacent the M8 weld nut having 20 mm (0.79 in) clearance behind the panel surface and 20 mm (0.79 in) clearance surrounding

the new electrical ground site.

3. Using GM approved residue-free solvent or equivalent, remove any grease from the surface surrounding the ground location and allow to dry.

Note
Ensure 20 mm (0.79 in) clearance is maintained behind the panel to be drilled.

4. Drill a 10 mm (0.40 in) diameter hole through the panel.
5. Remove paint and primer from the area surrounding the 10 mm (0.40 in) hole until bare metal is visible.
6. Select a M8 conductive bolt. Refer to the Parts Information section of this bulletin.
7. Using a small brush, apply Dielectric Lubricant GM P/N 12377900 (Canadian P/N 10953529) to the threads of the M8 conductive bolt.

Note
Fretting corrosion is a build-up of insulating, oxidized wear debris that can form when there is a small motion between electrical contacts. The
oxidized wear debris can accumulate at the electrical contact points causing the electrical resistance across the connection to increase. 

8. Carefully remove ANY corrosion or contamination that may be present on the electrical ground wire terminal. 
9. Install the electrical ground wire terminal and the M8 conductive bolt to the ground location.

10. Select a M8 conductive nut. Refer to the Parts Information section of this bulletin.
11. Install the M8 conductive nut to the bolt and:

Tighten
Tighten to 22 Nm (16 lb ft).

Note
The repair area MUST BE properly refinished to maintain a secure, stable and corrosion-free electrical ground. 

12. Refinish the repair area using an anti-corrosion primer. Refer to Anti-Corrosion Treatment and Repair in SI.
13. Verify proper system operation.

M8 Weld Nut Alternative Repair

Caution

Use only the GM-approved replacement fasteners with conductive finish for electrical ground repair.

1. If the M8 weld nut electrical ground location is not accessible from both sides of the panel, a M6 conductive rivet stud and a M6 conductive nut

may be used to secure the electrical ground wire terminal. 

2. Select a location adjacent the damaged M8 weld nut having 20 mm (0.79 in) clearance behind the panel surface and 20 mm (0.79 in) clearance

surrounding the M6 conductive rivet stud flange.

3. Using GM approved residue-free solvent or equivalent, remove any grease from the repair site and allow to dry.

Note
Ensure 20 mm (0.79 in) clearance is maintained behind the panel to be drilled.

4. Drill a 10 mm (0.40 in) diameter hole through the panel.

09-06-03-004D|Page 3469 > < 09-06-03-004D|Page 3467