buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

All Technical Service Bulletins for Choke Pull-off:|846C12|Page 2198 > < Customer Interest for Choke Pull-off:|846C12|Page 2195
Page 1
background image

Choke Pull-off: All Technical Service Bulletins
Engine - Hard Start/Poor Warm Up Performance

Bulletin    

84-6C-12

Date        

July '84

Ref. No.     

84-233-6C

SUBJECT:

CARBURETOR VACUUM BREAK TESTING PROCEDURE

MODELS AFFECTED:

ALL CARBURETORS EQUIPPED WITH VACUUM BREAKS

Hard starting or poor warm-up performance on a carbureted engine may be due to a leaking vacuum break unit. The vacuum break, sometimes called the
"choke pull-off", opens the carburetor choke valve against the tension of the thermostatic choke coil during cold engine start-up. A vacuum break unit
with a leaking diaphragm will not open the choke valve to the proper position, and may cause a cold engine to load up with fuel, resulting in black
exhaust smoke.

FIGURE 1 - BLEED ORIFICE LOCATIONS

VACUUM BREAK TESTING PROCEDURE:

1.

Determine whether the vacuum break has a bleed orifice. If it does, it should be plugged as shown. See Figure 1 for possible locations.

^

Most rear or secondary side units have a bleed.

^

Most front or primary side units do not.

All Technical Service Bulletins for Choke Pull-off:|846C12|Page 2198 > < Customer Interest for Choke Pull-off:|846C12|Page 2195