Blower Motor: Initial Inspection and Diagnostic Overview
Troubleshooting Hints

PERFORM BEFORE BEGINNING SYSTEM DIAGNOSIS

1. If the Blower Motor does not operate, check the HTR-A/C Fuse by visual inspection.
2. If the Blower Motor does not operate, check that ground G100 is clean and tight.
3. If the Blower Motor runs all of the time with the Ignition Switch "OFF," replace the Blower Motor Relay.
4. If the Blower Motor runs with the Ignition Switch in "RUN" and the Mode Selector "OFF," replace the Mode Selector.
5. Replace the Mode Selector if the Blower Motor runs with the Ignition Switch in "RUN" and the Mode Selector in one but not all of the following

modes: "MAX", "NORM", "VENT" "B/L," "HTR," "BLEND" and defrost.

^

Refer to Windows and Glass for Rear Defogger Control Assembly access.  See: Windows and Glass

^

Refer to System Diagnosis.  