buick Workshop Repair Guides

Buick Workshop Service and Repair Manuals

Generator Bracket Replacement|Page 10051 > < Generator Bracket Replacement
Page 1
background image

Alternator: Service and Repair
Generator Replacement

GENERATOR REPLACEMENT

The generator does not require periodic lubrication. The rotor shaft is mounted on bearings. Each bearing contains a permanent grease supply.
Periodically check the mounting bolts for tightness, and the drive belt tension. The drive belt is self-adjusting, within the operating limits of the
tensioner. Refer to Drive Belt Tensioner Diagnosis in Engine - 3.5L for tensioner information.

REMOVAL PROCEDURE

IMPORTANT:  Service the generator as a complete unit.

1. Disconnect the negative battery cable. 
2. Disconnect the windshield wiper transmission link in front of the wiper motor and position out of the way. 
3. Rotate the engine forward. Refer to Rotating the Engine for Service Access in Engine - 3.5L.
4. Remove the drive belt. 

5. Disconnect the generator battery positive terminal (1).
6. Disconnect the regulator electrical connector (2).

Generator Bracket Replacement|Page 10051 > < Generator Bracket Replacement