Terraza FWD V6-3.5L VIN 8 (2005)
Installation Procedure
1. Install the automatic level control sensor to the vehicle.
Notice: Install the height sensor bracket bolts (1).
2. Tighten the height sensor bracket bolts to 85 Nm (63 ft. lbs.).
3. Install the automatic level control sensor link onto the sensor arm ball stud.
4. Install the automatic level control height sensor electrical connector (1).
5. Lower the vehicle.
6. Install the ELC/TRAILER fuse.
7. Perform a diagnostic system check. Refer to Diagnostic System Check - Vehicle.