Blower Motor: Service and Repair
Blower Motor Replacement - Auxiliary (Without RPO Code  E59)

BLOWER MOTOR REPLACEMENT - AUXILIARY (WITHOUT RPO CODE E59)

REMOVAL PROCEDURE

1. Remove the accessory panel.

2. Remove the screws from the hinged cover.
3. Remove the cover from the rear trim panel.
4. Release the tabs and pull out the trim panel.
5. Disconnect the auxiliary blower motor electrical connector.
6. Disconnect the auxiliary blower motor resistor electrical connector.
7. Disconnect the auxiliary air temperature actuator electrical connector.

8. Remove the auxiliary blower motor mounting screws.
9. Remove the auxiliary blower motor from the blower motor housing.

INSTALLATION PROCEDURE

1. Install the auxiliary blower motor to the blower motor housing.
2. Install the auxiliary blower motor mounting screws.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the screws to 1.6 N.m (14 lb in).