cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

A/C - Odors on Hot/Humid Start Up|Page 6656 > < A/C - Odors on Hot/Humid Start Up|Page 6654
Page 1
background image

Evaporator Core: All Technical Service Bulletins
Procedure C (Install Afterblow Module, P/N 25533406)

The installation of the afterblow module as outlined in the following steps will turn the blower motor on approximately 50 minutes after the vehicle
ignition is turned off if the compressor was engaged for more than four minutes during the last ignition cycle. During the first 50 minutes after the vehicle
ignition is turned off, the evaporator will accumulate water condensate on the core. Cycling the blower motor at high speed for approximately five
minutes will force the water to be shed from the core and to drain from the evaporator case. This procedure is used to prevent the recurrence of the odor.
Be sure to advise the owner of this change in operation.

1.

If vehicle is equipped with Passenger Side Air Bag (1993 Eldorado/Seville), refer to the appropriate Service Information Manual and follow the
procedure to disable the SIR.

2.

Remove close out panel(s) and glove box as required to gain access to the circuits shown in the attached applicable wiring diagram. Refer to the
appropriate Service Information Manual for component location and service procedures.

A/C - Odors on Hot/Humid Start Up|Page 6656 > < A/C - Odors on Hot/Humid Start Up|Page 6654