Body Control Module: Reading and Clearing Diagnostic Trouble Codes
Data Parameters

BD20

The commanded blower voltage is read in volts from -2.9 to 18.0 Volts.

BD21

The coolant temperature is displayed in degrees Celsius (°C) from -40° to 151°C.  This value is sent from the PCM/ECM to the BCM. If this
circuit malfunctions as determined by the PCM/ECM, the PCM/ECM will send the BCM a "Failsoft" value for display.

BD22

The commanded air mix door position is displayed in percent (%). A value close to 0% represents a cold air mix and a value close to 100%
represents a warm air mix.

BD23

The actual air mix door position is displayed in percent (%). This value should follow the commanded air mix door position (BD22) except
when the door is commanded beyond its mechanical limits of travel. 

BD24

The air delivery mode is displayed as a number from 0 to 7. Each number is a code which represents the following air delivery modes:

0 = MAX A/C
1 = A/C
2 = Intermediate
3 = Heater
4 = OFF
5 = Normal Purge
6 = Cold Purge
7 = Front Defog

BD25

The in-car temperature is displayed in degrees Celsius (°C), from -40 to 102.

BD26

The actual outside temperature is displayed in degrees Celsius (°C), from -40° to 102°. This value represents actual sensor temperature and is
not restricted by the features used to minimize engine heat effects on the customer display value.

BD27

The A/C high side temperature (condenser output) is displayed in degrees Celsius (°C) from -40° to 215°.

BD28

The A/C low side temperature (evaporator input) is displayed in degrees Celsius (°C) from -40° to 102°.

BD32

The sunload temperature sensor is displayed in degrees Celsius (°C) from -40° to 102°.

BD40

The actual fuel level is read in gallons between 0 and 19.0 (the display can read to 25.0). This value represents actual sensor position and is not
restricted by the features used to eliminate fuel slosh affects on the customer display value.

BD41

The PRND321 is displayed in a four digit binary number unique to each gear position.

P = 0110
R = 0011
N = 1010
D = 1001
3 = 0000
2 = 0101
1 = 1100

BD42

The dimming pot is displayed in percent (%). A value close to 0% represents maximum dimming and a value close to 100% represents
maximum brightness.

BD43

The twilight delay pot is displayed in percent (%). A value close to 0% represents minimum delay time and a value close to 100% represents
maximum delay time.

BD44

The twilight photocell is displayed in percent (%). A value close to 0% represents daylight and value close to 100% represents darkness.

BD50

The battery voltage is read in volts between 0 and 16.3.

BD51

The generator field is displayed in percent (%). A value close to 0% represents minimum regulator on time and a value close to 100%
represents maximum regulator on time.

BD60

The vehicle speed is displayed in miles per hour (M.P.H.) from 0 to 159.

BD61

The engine speed is displayed in RPM from 0 to 6375.