Body Control Module: Description and Operation
Power Mode

POWER MODE DESCRIPTION AND OPERATION

SERIAL DATA POWER MODE

On vehicles that have several control modules connected by serial data circuits, one module is the power mode master (PMM). On this vehicle the
PMM is the dash integration module (DIM). The PMM receives 2 signals from the ignition switch.

To determine the correct power mode the PMM uses the following circuits:
-

Accessory voltage

-

Run/Crank voltage

FAIL-SAFE OPERATION

Since the operation of the vehicle systems depends on the power mode, there is a fail-safe plan in place should the power mode master (PMM) fail to
send a power mode message. The fail-safe plan covers those modules using exclusively serial data control of power mode as well as those modules
with discrete ignition signal inputs.

SERIAL DATA MESSAGES

The modules that depend exclusively on serial data messages for power modes stay in the state dictated by the last valid PMM message until they can
check for the engine run flag status on the serial data circuits. If the PMM fails, the modules monitor the serial data circuit for the engine run flag
serial data. If the engine run flag serial data is True, indicating that the engine is running, the modules fail-safe to RUN. In this state the modules and
their subsystems can support all operator requirements. If the engine run flag serial data is False, indicating that the engine is not running, the modules
fail-safe to OFF-AWAKE. In this state the modules are constantly checking for a change status message on the serial data circuits and can respond to
both local inputs and serial data inputs from other modules on the vehicle.

DISCRETE IGNITION SIGNALS

Those modules that have discrete ignition signal inputs also remain in the state dictated by the last valid PMM message received on the serial data
circuits. They then check the state of their discrete ignition input to determine the current valid state. If the discrete ignition input is active, battery
positive voltage, the modules will fail-safe to the RUN power mode. If the discrete ignition input is not active, open or 0 voltage, the modules will
fail-safe to OFF-AWAKE. In this state the modules are constantly checking for a change status message on the serial data circuits and can respond to
both local inputs and serial data inputs from other modules on the vehicle.