17. Remove and transfer the following components from the washer solvent container:
-
the washer pump
-
the washer level sensor
-
the horizontal bracket
-
the washer container cap
INSTALLATION PROCEDURE
1. Install the following components to the washer solvent container:
-
the washer pump
-
the washer level sensor
-
the horizontal bracket
-
the washer container cap
2. Position the washer solvent container filler neck up through the radiator support.
3. Engage the electrical harness retainer clip to the washer solvent container.
4. Engage the container over the stud on the tie bar outer reinforcement panel.
5. Engage the clinch nut stud (3) to the key hole slot (1) in the body rail.
6. Ensure the washer solvent container is positioned over the stud (3) on the tie bar outer reinforcement panel.
7. Install the nuts (1,2,6) to the washer solvent container.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the nuts (1,2,6) to 6 N.m (53 lb in).
8. Tighten the clinch nut.