Variable Valve Timing Actuator: Service and Repair
Camshaft Position Actuator Replacement - Bank 2 (Left Side) Exhaust

CAMSHAFT POSITION ACTUATOR REPLACEMENT - BANK 2 (LEFT SIDE) EXHAUST

Tools Required: EN 46108 Timing Chain Retention Tool

Removal Procedure

1. Remove the upper intake manifold with the lower intake manifold.
2. Remove the left bank camshaft cover.
3. Remove the camshaft sensors.
4. Remove the camshaft position actuator solenoid.

Important:  Rotate the crankshaft balancer in a clockwise rotation ONLY.

5. Rotate the crankshaft using the crankshaft balancer bolt until the camshafts are in a neutral (low tension) position. The camshaft flats will be

parallel with the camshaft cover rail (1).

Notice:  A wrench must be used on the hex of the camshaft when loosening or tightening in order to prevent component damage. Failure to
prevent the torque reaction against the timing drive chain can lead to timing drive chain failure.