Housing Assembly HVAC: Service and Repair

HVAC MODULE ASSEMBLY REPLACEMENT

TOOLS REQUIRED

-

J 39400-A Halogen Leak Detector

-

J 38185 Hose Clamp Pliers

-

J 45689 A/C Quick Joint Tool

REMOVAL PROCEDURE

1. Recover the refrigerant.
2. Remove the battery.
3. Drain the coolant.

4. Using the J 38185 disconnect the heater inlet hose (1).

5. Using the J 38185 disconnect the heater outlet hose (1).
6. Disconnect both A/C lines at the cowl.