3. Install the bolt (2) securing the surge tank outlet pipe (1) to the engine rear lift bracket.

Tighten the surge tank outlet pipe to engine rear lift bracket bolt to 9 Nm (80 inch lbs.).

4. Install the bolt (6) securing the surge tank outlet pipe (1) to the vent housing.

Tighten the surge tank outlet pipe to vent housing bolt to 9 Nm (80 inch lbs.).

5. Connect the heated oxygen sensor connector (1) to the bracket (3).

6. Position the J 38185 to the clamp in order to connect the surge tank outlet hose (2) to the surge tank (1).
7. Install the wiper motor module. 
8. Fill the cooling system. 

Left Hand Drive|Page 2730 > < Left Hand Drive|Page 2728