CTS V6-3.2L VIN N (2003)
-
Do not allow solvents and lubricants to come in contact with the sensing elements.
-
Use a small amount of a soap based solution in order to aid in the installation.
INSTALLATION PROCEDURE
1. Insert the MAF/IAT sensor into the air cleaner assembly with the connector terminal orientated upward.
2. Install the 2 screws securing the MAF/IAT sensor to the air cleaner assembly.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten
Tighten the MAF/IAT sensor screws to 2.25 N.m (20 lb in).
3. Connect the air intake duct hose to MAF/IAT sensor.
4. Connect the electrical connector (1) to the MAF/IAT sensor (2).