Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 2 (Left Side) Exhaust

CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 2 (LEFT SIDE) EXHAUST (RPO LP1,
LY7)

Removal Procedure

1. Turn the ignition OFF.

Important: Do not disconnect the power steering fluid lines/hoses from the reservoir.

2. Remove the power steering fluid reservoir bolts and reposition the power steering fluid reservoir in order to provide access.

3. Remove the camshaft position (CMP) actuator valve electrical connector.

4. Remove the CMP actuator valve bolt.

5. Remove the CMP actuator valve.

6. Inspect the CMP actuator valve seal for damage and replace as necessary.

Installation Procedure

1. Inspect the CMP actuator valve seal for damage. Replace the seal if necessary.