8. The liftgate hydraulic actuator pump must rest in the horizontal position for one minute before the hydraulic fluid level is inspected. The level

must be above the + mark. 

9. Install the pump without the trim and inspect for proper operation and fluid level. The fluid level can be checked after cycling the liftgate 3-5 times

to ensure proper fluid level. If the fluid is still low repeat the procedure.

10. Install the liftgate hydraulic pump after inspection. Refer to Liftgate Hydraulic Pump Replacement   (See: Trunk / Liftgate Hydraulic

Pump/Service and Repair/Liftgate Hydraulic Pump Replacement).