cadillac Workshop Repair Guides

Cadillac Workshop Service and Repair Manuals

Symptoms - Data Communications|Page 4088 > < Symptoms - Data Communications|Page 4086
Page 2
background image

-

Vehicle stability enhancement system warning lights and messages.

-

PRNDL gear indicator position errors.

-

Tire Pressure Monitor (TPM) system warning lights.

Reference Information
Schematic Reference

Data Communication Schematics   (See: Diagrams/Electrical Diagrams)
Connector End View Reference

*

Component Connector End Views   (See: Diagrams/Connector Views)

*

Splice Pack Connector End Views   (See: Diagrams/Connector Views)

Description and Operation

Data Link Communications Description and Operation   (See: Description and Operation)
Electrical Information Reference

*

Circuit Testing   (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit Testing/Circuit Testing)

*

Connector Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/Connector Repairs/Connector Repairs)

*

Testing for Intermittent Conditions and Poor Connections   (See: Testing and Inspection/Component Tests and General Diagnostics/Circuit
Testing/Testing for Intermittent Conditions and Poor Connections)

*

Wiring Repairs   (See: Testing and Inspection/Component Tests and General Diagnostics/Wiring Repairs/Wiring Repairs)

Circuit/System Testing

Note:  Use the schematic to identify the following:

*

Control modules the vehicle is equipped with

*

Control module locations on the low speed GMLAN serial data circuit

*

Each control module's low speed GMLAN serial data circuit terminals

1. Attempt to communicate with all control modules on the low speed GMLAN serial data circuit, refer to Data Link References   (See: Initial

Inspection and Diagnostic Overview). Communications should not be available with two or more control modules on the low speed GMLAN
serial data circuit.

‹› If only one control module is not communicating, diagnose that control module only. Refer to DTC U0100-U0299   (See: Testing and

Inspection/Diagnostic Trouble Code Tests and Associated Procedures/U Code Charts/U0100).

‹› If one or more control modules are communicating but not all, refer to Testing the Serial Data Circuit for an Open/High Resistance.

2. Disconnect the scan tool from the DLC. The following tests will be done at the DLC connector. 
3. All access doors closed, ignition OFF for 60 seconds, test for less than 10 ohm between the ground circuit terminal 5 and ground.

‹› If greater than the specified range, test the ground circuit for an open/high resistance.

4. Ignition ON, test for less than 4.5 V between the serial data circuit terminal 1 and ground. 

‹› If greater than the specified range, test the serial data circuit for a short to voltage, refer to Testing the Serial Data Circuit for a Short to

Voltage.

5. Ignition OFF for 60 seconds, test for greater than 100 ohm between the serial data circuit terminal 1 and ground.

‹› If not the specified value, test the serial data circuit for a short to ground, refer to Testing the Serial Data Circuits for a Short to ground.

6. Disconnect the harness connector at the JX 201 splice pack.
7. Test for less than 2 ohm between the serial data circuit terminal 1 and the JX 201 splice pack terminal 1. 

‹› If greater than the specified range, test the serial data circuit for an open/high resistance. If the circuits test normal, replace the splice pack.

Testing the Serial Data Circuits for a Short to Voltage

1. Ignition OFF, disconnect the harness connectors at the JX 201 and JX 301 splice packs, as equipped.
2. Ignition ON, test for less than 4.5 V between the DLC serial data circuit terminal 1 and ground.

‹› If greater than the specified range, repair the short to voltage.

3. Test for less than 4.5 V between each serial data circuit and ground.

Symptoms - Data Communications|Page 4088 > < Symptoms - Data Communications|Page 4086