3. Pull on both sides of the quick-connect fitting to make sure the connection is secure.

4. Install the retainer to the quick-connect fitting.
5. Inspect for leaks using the following procedure:

1. Turn the ignition ON, with the engine OFF for 2 seconds.
2. Turn the ignition OFF, for 10 seconds.
3. Turn the ignition ON, with the engine OFF for 2 seconds.
4. Turn the ignition OFF.
5. Inspect for leaks.